Inline temperature + mid-range chlorine (Cl2) sensor (0-400ppm). Dual 4-20mA + RS-485, 7-pin.

The Pyxis ST-607 is an inline, temperature-compensated sensor that measures mid-range chlorine (Cl2) concentration from 0-400ppm. It provides dual 4-20mA analog outputs plus RS-485 Modbus communication through a single 7-pin connector, allowing straightforward integration into chlorine disinfection monitoring and control systems.
The Pyxis ST-607 is an inline, temperature-compensated sensor that measures mid-range chlorine (Cl2) concentration from 0-400ppm. It fills the gap between low-range and high-range chlorine instruments, giving plants a dedicated option for mid-level chlorine disinfection monitoring.
Temperature compensation is built in, so the sensor automatically adjusts its chlorine readings as process water temperature fluctuates, helping maintain measurement accuracy throughout normal operating conditions. Output is delivered through dual 4-20mA analog signals plus RS-485 Modbus, via a single 7-pin connector.
The combined analog and digital output allows the ST-607 to serve both traditional analog control loops and networked PLC/SCADA systems, making it straightforward to integrate into chlorine disinfection monitoring and control systems already in place.
The 0-400ppm range and built-in temperature compensation give accurate Cl2 readings for process chlorination systems even as water conditions vary.
Dual 4-20mA analog outputs combined with RS-485 Modbus let the sensor communicate with both analog controllers and networked control systems through one 7-pin connector.
It measures mid-range chlorine (Cl2) concentration from 0-400ppm.
Yes, the ST-607 is temperature-compensated and automatically corrects chlorine readings as process water temperature changes.
Dual 4-20mA analog outputs plus RS-485 Modbus communication, delivered through a single 7-pin connector.
Yes — the dual analog/digital output design is intended to allow straightforward integration into existing chlorine disinfection monitoring and control systems.
Stainless steel dechlorination sensor measuring Free Chlorine (0-5ppm) and Sulfite (0-100ppm) simultaneously, plus pH. Sensor only, no flow reservoir. Dual 4-20mA + RS-485.
Stainless steel free chlorine + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.