Inline digital refractometer measuring refractive index, %BRIX, and both mono-ethylene and mono-propylene glycol concentration in one sensor. Suited to closed-loop glycol systems, sugar process monitoring, and data centre cooling loops.

Pyxis Lab
Refractive Index Sensor
Glycol & Process Monitoring Line

Pyxis RT-100 PRISM Inline Refractometer

Model:
RT-100 PRISM
Brand:
Pyxis Lab

The RT-100 PRISM is an inline digital refractometer that converts the refractive index of a liquid sample directly into accurate concentration values for glycol and process fluid monitoring. Built-in temperature-compensated equations cover Mono-Ethylene Glycol, Mono-Propylene Glycol, Sugar Content (BRIX), and Advanced Low Viscosity Fluid from a single sensor body. It operates as a stand-alone unit with local display and data logging, or integrates with a PLC, DCS, or third-party controller via 4-20mA and RS-485 Modbus.

Multi-parameter measurement — reads MEG, MPG, BRIX, and ALV concentration from one sensor body
Tool-free cleaning — Tri-Clamp flow assembly allows removal for cleaning without tools
Multi-parameter measurement — reads MEG, MPG, BRIX, and ALV concentration from one sensor body

Description

The RT-100 PRISM is an inline digital refractometer that reads the refractive index of a liquid sample and converts it directly into accurate concentration values for water and process fluid applications. It can run as a stand-alone unit with a local display, push-button interface, and onboard data logging, or integrate into a PLC, DCS, or third-party controller via 4-20mA and RS-485 Modbus outputs.

Built-in temperature-compensated equations convert refractive index readings into percentage concentration for Mono-Ethylene Glycol (MEG), Mono-Propylene Glycol (MPG), Sugar Content (BRIX), and Advanced Low Viscosity Fluid (ALV), covering a wide span of glycol and process monitoring duties from a single sensor body.

Construction is 316L stainless steel with a sapphire measurement window, rated IP67, and it installs into a Tri-Clamp flow assembly with a 3/4″ NPT flange, allowing removal for cleaning without tools. For fouled or contaminated streams, Pyxis recommends routine sensor eye cleaning or fitting the ultrasonic cleaning module accessory. The optional MA-CR Bluetooth Adapter adds wireless data access via the uPyxis app, including up to 56 days of stored historical readings at 1-minute intervals.

Why Use This

One Sensor, Multiple Parameters

Covers glycol concentration, BRIX, and ALV measurement in a single inline sensor body, reducing the need for multiple instruments.

Easy Integration and Maintenance

Local display with data logging plus 4-20mA and RS-485 Modbus outputs support stand-alone use or PLC/DCS integration, and the Tri-Clamp design allows tool-free cleaning.

Wireless Monitoring

The optional MA-CR Bluetooth Adapter provides wireless data access and up to 56 days of stored readings through the uPyxis app.

Applications

  • Glycol concentration monitoring — MEG and MPG measurement for HVAC and process fluid loops
  • Sugar/BRIX process monitoring — measures sugar content in process fluid applications
  • PLC/DCS-integrated process control — 4-20mA and RS-485 Modbus outputs for automated dosing or blending control
  • Fouling-prone fluid streams — tool-free Tri-Clamp removal and optional ultrasonic cleaning module simplify upkeep

FAQ

What fluids and parameters can the RT-100 PRISM measure?

It measures refractive index directly and converts it into percentage concentration for MEG, MPG, BRIX, and ALV, using built-in temperature-compensated equations.

How does it connect to my control system?

It offers two 4-20mA outputs and RS-485 Modbus for integration with a PLC, DCS, or third-party controller, or it can run stand-alone with its local display and data logging.

How is it installed, and can it be cleaned easily?

It installs into a Tri-Clamp flow assembly with a 3/4″ NPT flange, allowing removal for cleaning without tools; in fouled streams, Pyxis recommends routine sensor eye cleaning or the optional ultrasonic cleaning module.

What are the pressure, flow, and temperature limits?

Maximum sample pressure/flow is 0.98MPa / 9.8ft/s, and sample temperature range is -20 to 70°C.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Pyxis ST-765SS-O3 Ozone + pH Sensor – Sensor Only (Stainless Steel)

Stainless steel ozone + pH sensor, 0-2ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.

Pyxis ST-765SS-FCL Free Chlorine + pH Sensor with FR-50 Flow Reservoir Kit (Stainless Steel)

Stainless steel free chlorine + pH sensor, 0-5ppm, complete with FR-50 flow reservoir kit and rotameter. Dual 4-20mA + RS-485, 8-pin connector.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Pyxis RT-100 PRISM Inline Refractometer
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?

Our engineers are ready to evaluate your requirements and recommend the right solution.