CPVC oxidizer + pH + temperature sensor measuring Chlorine Dioxide (ClO2) 0.00-5.00ppm (auto-range) with pH compensation to pH 9.0. Replaceable front-loading reference electrode, Bluetooth-ready with MA-CR adapter.

The ST-765P-CLO is a CPVC-bodied, membrane-less sensor that measures Chlorine Dioxide alongside pH and temperature in a single probe, using Pyxis Lab's bare-gold electrochemical detection technology. Internal pH compensation up to pH 9.0 keeps oxidizer readings consistent with DPD wet chemistry and compliant with USEPA-334.0 and ISO-7393 methodology. The replaceable, front-loading reference electrode avoids the membrane and gel replacement of older amperometric designs, giving a typical service life of up to 2 years.
The ST-765P-CLO is a CPVC-bodied, membrane-less sensor that measures Chlorine Dioxide alongside pH and temperature in a single probe, using Pyxis Lab’s bare-gold electrochemical detection technology. Internal pH compensation up to pH 9.0 keeps oxidizer readings consistent with DPD wet chemistry and compliant with USEPA-334.0 and ISO-7393 methodology.
The reference electrode assembly is replaceable and front-loading, developed independently by Pyxis Lab to avoid the membrane and gel replacement associated with older amperometric designs. This gives reduced polarization time on startup and a typical electrode service life of up to 2 years, with a flat, fouling-resistant front-end that’s straightforward to clean in place.
Dual isolated 4-20mA outputs plus RS-485 Modbus support integration with a PLC, SCADA, or third-party controller, and the optional MA-CR Bluetooth Adapter adds wireless calibration and diagnostics via the uPyxis mobile app. The CPVC body suits clean water applications including potable water, secondary water supply, domestic water, and decorative water features.
Internal pH and temperature compensation up to pH 9.0 keeps Chlorine Dioxide readings aligned with DPD wet chemistry and USEPA-334.0 / ISO-7393 methodology.
The replaceable, front-loading reference electrode avoids membrane and gel replacement, with a typical service life of up to 2 years and reduced startup polarization time.
Dual isolated 4-20mA outputs and RS-485 Modbus connect to a PLC, SCADA, or third-party controller, with optional Bluetooth calibration via the MA-CR adapter.
It measures Chlorine Dioxide alongside pH and temperature in a single probe, with oxidizer precision of ±0.01mg/L or 1% of value.
The replaceable, front-loading reference electrode has a typical service life of up to 2 years, avoiding the membrane and gel replacement of older designs.
It’s compliant with USEPA-334.0 and ISO-7393 methodology and carries CE / RoHS regulation.
Yes, via dual isolated 4-20mA analog outputs plus RS-485 Modbus for integration with a PLC, SCADA, or third-party controller.
High-temperature inline digital refractometer measuring refractive index, %BRIX, and glycol concentration up to 120°C. Stainless steel Tri-Clamp body, IP67, built-in Bluetooth 5.0.
CPVC dechlorination sensor measuring Free Chlorine (0.00-5.00ppm) and Sulfite (0.0-100.0ppm) simultaneously, plus pH and temperature. Replaceable front-loading reference electrode, Bluetooth-ready with MA-CR adapter.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.