Skip to main content

Autoflo Technology

Pyxis ST-765SS-NCL Monochloramine + pH Sensor – Sensor Only (Stainless Steel)

Stainless steel monochloramine + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.

Pyxis Lab
Electrochemical Sensor
Potable Water Line

Pyxis ST-765SS-NCL Monochloramine + pH Sensor – Sensor Only (Stainless Steel)

Model:
ST-765SS-NCL
Brand:
Pyxis Lab

The Pyxis ST-765SS-NCL is a stainless steel, membrane-less multi-parameter sensor that measures monochloramine, pH, and temperature in a single probe using Pyxis Lab's bare-gold electrochemical detection technology. It is suited to chloramine-based disinfection monitoring in potable and process water, and ships sensor-only without a flow reservoir kit. Dual isolated 4-20mA outputs plus RS-485 Modbus support direct integration with a PLC, SCADA, or third-party controller.

Long electrode life — replaceable, front-loading reference electrode assembly rated for up to 2 years of service
Built for chloramine disinfection — tracks monochloramine and pH together in potable and process water
Long electrode life — replaceable, front-loading reference electrode assembly rated for up to 2 years of service

Description

The Pyxis ST-765SS-NCL is a stainless steel, membrane-less multi-parameter sensor that measures monochloramine, pH, and temperature from a single probe, using Pyxis Lab’s bare-gold electrochemical detection technology. It ships sensor-only, without a flow reservoir kit, for installation into an existing housing.

Monochloramine is measured over a 0-5ppm range, making the sensor well suited to chloramine-based disinfection monitoring in potable and process water. The reference electrode assembly is replaceable and front-loading, reducing startup polarisation time and giving a typical service life of up to 2 years.

Dual isolated 4-20mA outputs plus RS-485 Modbus, via an 8-pin connector, support direct integration with a PLC, SCADA, or third-party controller.

Why Use This

Chloramine disinfection monitoring

Tracks monochloramine alongside pH in one probe, supporting disinfection control in potable and process water systems.

Reduced maintenance

The replaceable, front-loading reference electrode typically lasts up to 2 years and cuts startup polarisation time.

Flexible controller integration

Dual isolated 4-20mA outputs and RS-485 Modbus connect directly to a PLC, SCADA, or third-party controller via an 8-pin connector.

Applications

  • Potable water disinfection monitoring — tracks monochloramine and pH in drinking water systems
  • Chloramine-based process water disinfection — continuous monitoring for treatment programmes
  • PLC/SCADA-integrated control loops — dual 4-20mA and RS-485 Modbus outputs for direct system tie-in

FAQ

What water types is this sensor designed for?

It is suited to chloramine-based disinfection monitoring in potable and process water.

What is the monochloramine measurement range?

The sensor measures monochloramine over a 0-5ppm range, alongside pH and temperature.

Does it include a flow reservoir kit?

No, it ships sensor-only, with no flow reservoir kit included.

What is the expected electrode life?

The replaceable, front-loading reference electrode assembly has a typical service life of up to 2 years.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Pyxis ST-765P-CLO Chlorine Dioxide + pH Sensor (CPVC)

CPVC oxidizer + pH + temperature sensor measuring Chlorine Dioxide (ClO2) 0.00-5.00ppm (auto-range) with pH compensation to pH 9.0. Replaceable front-loading reference electrode, Bluetooth-ready with MA-CR adapter.

Pyxis ST-500 Inline PTSA Sensor

Real-time inline PTSA sensor for tracking inhibitor dose in cooling and boiler water treatment programmes. Measures PTSA using fluorescence technology across 0–300ppb with automatic colour and turbidity compensation, holding accuracy even in samples with iron contamination or elevated turbidity.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Pyxis ST-765SS-NCL Monochloramine + pH Sensor – Sensor Only (Stainless Steel)
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?