Inline temperature + low range chlorine dioxide sensor (0-100ppm), 365nm. Dual 4-20mA + RS-485, 7-pin.

Pyxis Lab
Temperature-Compensated Sensor
Water Treatment

Pyxis ST-605 Inline Temperature + Low Range ClO2 Sensor

Model:
ST-605
Brand:
Pyxis Lab

The Pyxis ST-605 is an inline, temperature-compensated sensor that measures low-range chlorine dioxide (ClO2) using 365nm detection, covering 0-100ppm. It provides dual 4-20mA analog outputs plus RS-485 Modbus communication through a single 7-pin connector, allowing straightforward integration into existing ClO2 disinfection monitoring systems.

Temperature compensation — automatically corrects ClO2 readings as process water temperature changes
Dual output design — dual 4-20mA outputs plus RS-485 Modbus feed both analog controllers and networked SCADA systems
Temperature compensation — automatically corrects ClO2 readings as process water temperature changes

Description

The Pyxis ST-605 is an inline, temperature-compensated sensor designed to measure low-range chlorine dioxide (ClO2) concentration using 365nm optical detection, covering 0-100ppm. It is intended for facilities using ClO2 as a disinfectant and needing accurate low-range monitoring rather than broad-spectrum detection.

Because water temperature affects disinfectant readings, the ST-605 automatically compensates for temperature shifts to keep measurements reliable across changing process conditions. It communicates through dual 4-20mA analog outputs plus RS-485 Modbus, delivered via a single 7-pin connector.

This dual-output design allows the sensor to serve both analog-based control panels and digital PLC/SCADA networks from one device, making it straightforward to drop into existing ClO2 disinfection monitoring systems with minimal rewiring.

Why Use This

Precise Low-Range ClO2 Detection

365nm-based low-range detection covering 0-100ppm, with temperature compensation, keeps chlorine dioxide readings accurate as process conditions vary.

Flexible System Integration

Dual 4-20mA analog outputs combined with RS-485 Modbus let the sensor communicate with both analog controllers and networked control systems through one 7-pin connector.

Applications

  • ClO2 disinfection monitoring — low-range (0-100ppm) chlorine dioxide measurement in treated water
  • Retrofit into existing ClO2 monitoring systems — dual output design simplifies integration
  • PLC/SCADA-based disinfection control — RS-485 Modbus enables networked automation

FAQ

What does the ST-605 measure and over what range?

It measures low-range chlorine dioxide (ClO2) using 365nm detection, covering 0-100ppm.

Is the reading affected by water temperature?

No — the ST-605 is temperature-compensated and automatically adjusts ClO2 readings as process water temperature changes.

What outputs are available for integration with a control system?

Dual 4-20mA analog outputs plus RS-485 Modbus communication, all through a single 7-pin connector.

Can this sensor integrate with an existing SCADA system?

Yes. The RS-485 Modbus output allows direct digital integration with PLC/SCADA networks alongside the analog outputs.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Pyxis ST-765SS-SO3 Sulfite + pH Sensor – Sensor Only (Stainless Steel)

Stainless steel sulfite + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.

Pyxis ST-765P-DCL Free Chlorine + Sulfite + pH Sensor (CPVC)

CPVC dechlorination sensor measuring Free Chlorine (0.00-5.00ppm) and Sulfite (0.0-100.0ppm) simultaneously, plus pH and temperature. Replaceable front-loading reference electrode, Bluetooth-ready with MA-CR adapter.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Pyxis ST-605 Inline Temperature + Low Range ClO2 Sensor
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?

Our engineers are ready to evaluate your requirements and recommend the right solution.