Inline temperature + low range chlorine dioxide sensor (0-100ppm), 365nm. Dual 4-20mA + RS-485, 7-pin.

The Pyxis ST-605 is an inline, temperature-compensated sensor that measures low-range chlorine dioxide (ClO2) using 365nm detection, covering 0-100ppm. It provides dual 4-20mA analog outputs plus RS-485 Modbus communication through a single 7-pin connector, allowing straightforward integration into existing ClO2 disinfection monitoring systems.
The Pyxis ST-605 is an inline, temperature-compensated sensor designed to measure low-range chlorine dioxide (ClO2) concentration using 365nm optical detection, covering 0-100ppm. It is intended for facilities using ClO2 as a disinfectant and needing accurate low-range monitoring rather than broad-spectrum detection.
Because water temperature affects disinfectant readings, the ST-605 automatically compensates for temperature shifts to keep measurements reliable across changing process conditions. It communicates through dual 4-20mA analog outputs plus RS-485 Modbus, delivered via a single 7-pin connector.
This dual-output design allows the sensor to serve both analog-based control panels and digital PLC/SCADA networks from one device, making it straightforward to drop into existing ClO2 disinfection monitoring systems with minimal rewiring.
365nm-based low-range detection covering 0-100ppm, with temperature compensation, keeps chlorine dioxide readings accurate as process conditions vary.
Dual 4-20mA analog outputs combined with RS-485 Modbus let the sensor communicate with both analog controllers and networked control systems through one 7-pin connector.
It measures low-range chlorine dioxide (ClO2) using 365nm detection, covering 0-100ppm.
No — the ST-605 is temperature-compensated and automatically adjusts ClO2 readings as process water temperature changes.
Dual 4-20mA analog outputs plus RS-485 Modbus communication, all through a single 7-pin connector.
Yes. The RS-485 Modbus output allows direct digital integration with PLC/SCADA networks alongside the analog outputs.
Stainless steel sulfite + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.
CPVC dechlorination sensor measuring Free Chlorine (0.00-5.00ppm) and Sulfite (0.0-100.0ppm) simultaneously, plus pH and temperature. Replaceable front-loading reference electrode, Bluetooth-ready with MA-CR adapter.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.