Stainless steel ozone + pH sensor, 0-2ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.

The Pyxis ST-765SS-O3 is a stainless steel, membrane-less multi-parameter sensor that measures ozone, pH, and temperature in a single probe using Pyxis Lab's bare-gold electrochemical detection technology. It ships sensor-only, without a flow reservoir kit, for installation into an existing housing. Dual isolated 4-20mA outputs plus RS-485 Modbus support direct integration with a PLC, SCADA, or third-party controller.
The Pyxis ST-765SS-O3 is a stainless steel, membrane-less multi-parameter sensor that measures ozone, pH, and temperature from a single probe. It is built on Pyxis Lab’s bare-gold electrochemical detection technology and ships sensor-only, without a flow reservoir kit, for installation into an existing housing.
The reference electrode assembly is replaceable and front-loading, reducing polarisation time on startup and delivering a typical service life of up to 2 years, which cuts down on maintenance visits. Ozone measurement covers a 0-2ppm range.
Dual isolated 4-20mA outputs plus RS-485 Modbus, via an 8-pin connector, allow the sensor to integrate directly with a PLC, SCADA system, or third-party controller, making it suited to plants that need ozone residual tracking alongside pH in one process tap.
Measures ozone, pH, and temperature simultaneously, reducing the number of separate sensors needed in a control loop.
The replaceable, front-loading reference electrode typically lasts up to 2 years and cuts startup polarisation time.
Dual isolated 4-20mA outputs and RS-485 Modbus connect directly to a PLC, SCADA, or third-party controller via an 8-pin connector.
No. The ST-765SS-O3 ships sensor-only, with no flow reservoir kit included, for installation into an existing housing.
The reference electrode assembly is replaceable and front-loading, with a typical service life of up to 2 years.
It provides two isolated 4-20mA analog outputs plus RS-485 Modbus, connected via an 8-pin connector, for integration with a PLC, SCADA, or third-party controller.
The sensor measures ozone over a 0-2ppm range, alongside pH and temperature.
Inline fluorescence sensor for real-time chlorophyll-a (algae) monitoring, reagent-free. Suited to raw water intake and cooling water source monitoring.
Inline fluorometer and turbidimeter measuring PTSA (0–500ppb) and turbidity (0–200NTU) with colour and turbidity compensation. UPVC body suited to pressures below 100psi.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.