Inline temperature + acidified sodium chlorite (NaClO2) sensor (0-1,200ppm), 254nm. Dual 4-20mA + RS-485, 7-pin.

The Pyxis ST-606 is an inline, temperature-compensated sensor that measures acidified sodium chlorite (ASC / NaClO2) using 254nm detection, covering 0-1,200ppm. It provides dual 4-20mA analog outputs plus RS-485 Modbus communication through a single 7-pin connector, enabling direct integration into ASC-based disinfection monitoring systems.
The Pyxis ST-606 is an inline, temperature-compensated sensor built to measure acidified sodium chlorite (ASC / NaClO2) concentration using 254nm optical detection, covering a range of 0-1,200ppm. It is designed for facilities using ASC-based disinfection chemistries that require accurate, continuous inline measurement.
The sensor automatically compensates for temperature variation in the process stream, keeping ASC readings consistent as water conditions change. It outputs via dual 4-20mA analog signals plus RS-485 Modbus, delivered through a single 7-pin connector for simplified field wiring.
With both analog and digital communication built in, the ST-606 can feed conventional analog controllers as well as networked PLC/SCADA systems, enabling direct integration into existing ASC-based disinfection monitoring setups.
254nm-based detection covering 0-1,200ppm, with temperature compensation, delivers reliable acidified sodium chlorite readings for antimicrobial water treatment programs.
Dual 4-20mA analog outputs combined with RS-485 Modbus let the sensor communicate with both analog controllers and networked control systems through one 7-pin connector.
It measures acidified sodium chlorite (ASC / NaClO2) using 254nm detection, over a range of 0-1,200ppm.
Yes, the ST-606 is temperature-compensated and automatically adjusts ASC readings as process water temperature shifts.
It provides dual 4-20mA analog outputs plus RS-485 Modbus communication through a single 7-pin connector.
Yes, the RS-485 Modbus output enables digital integration with PLC/SCADA networks in addition to the analog signals.
Inline fluorescence sensor for real-time chlorophyll-a (algae) monitoring, reagent-free. Suited to raw water intake and cooling water source monitoring.
Stainless steel inline PTSA sensor built to drop directly into WALCHEM and other industry-standard tee assemblies. Measures PTSA 0–300ppb with colour and turbidity compensation, no plumbing modification needed.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.