Skip to main content

Autoflo Technology

Pyxis ST-587 Inline PTSA + Turbidity Sensor

Inline fluorometer and turbidimeter measuring PTSA (0–500ppb) and turbidity (0–200NTU) with colour and turbidity compensation. UPVC body suited to pressures below 100psi.

Pyxis
Fluorometer & Turbidimeter
Cooling Water Line

Pyxis ST-587 Inline PTSA + Turbidity Sensor

Model:
ST-587
Brand:
Pyxis

The Pyxis ST-587 is an inline fluorometer and turbidimeter that measures PTSA concentration (a common fluorescent tracer) and turbidity in the same sample stream, using LED UV and warm white light sources. Extra photo-electric components automatically compensate for sample colour and turbidity that would otherwise interfere with a standard fluorometer reading. The UPVC body suits application pressures below 100psi, with 4-20mA and RS-485 Modbus outputs for direct controller integration.

Automatic interference compensation — colour and turbidity compensation keeps PTSA readings accurate without manual correction
Easy-to-clean design — short fluidic channel is simpler to maintain than fluorometers with a flat sensor face or long, narrow cell
Automatic interference compensation — colour and turbidity compensation keeps PTSA readings accurate without manual correction

Description

The Pyxis ST-587 Series inline fluorometer and turbidimeter measures PTSA concentration and turbidity in the same sample stream, using both LED UV and warm white light sources. PTSA is commonly used as a fluorescent tracer in cooling and process water treatment, and this variant covers a 0-500ppb PTSA range and 0-200NTU turbidity range.

Extra photo-electric components measure sample colour and turbidity, giving automatic compensation to eliminate interference that would otherwise affect a standard fluorometer, along with in-situ sensor cleanliness diagnostics. Its short fluidic channel design is easier to clean than fluorometers with a flat distal sensor surface or a long, narrow fluidic cell, and a narrow-wavelength-band gallium phosphide photodiode with temperature- and humidity-resistant optical filters keeps it stable across a wide range of ambient conditions.

The sensor connects to any device accepting isolated or non-isolated 4-20mA input, or RS-485 Modbus, and calibration and cleaning are handled via the MA-CR Bluetooth/USB adapter and uPyxis app. This UPVC-bodied version suits application pressures below 100psi (6.9 Bar); for higher-pressure systems, see the ST-587SS stainless steel variant.

Why Use This

Reliable readings despite interference

Automatic colour and turbidity compensation eliminates interference that would otherwise distort a standard fluorometer reading.

Lower maintenance

The short fluidic channel design is easier to clean than fluorometers with a flat sensor face or a long, narrow fluidic cell.

Stable across ambient conditions

A gallium phosphide photodiode with temperature- and humidity-resistant optical filters keeps performance stable without separate environmental controls.

Applications

  • Cooling water tracer monitoring — PTSA fluorescent tracer tracking in cooling water treatment
  • Process water treatment — combined PTSA and turbidity monitoring in one sensor
  • Standard-pressure water systems — suited to applications below 100psi (6.9 Bar)

FAQ

What does this sensor measure?

It measures PTSA concentration (0-500ppb) and turbidity (0-200NTU) in the same sample stream, using LED UV and warm white light sources.

What is the maximum operating pressure?

The UPVC body suits application pressures below 100psi (6.9 Bar); for higher-pressure systems, the ST-587SS stainless steel variant is available instead.

How does it handle sample colour or turbidity interference?

Extra photo-electric components measure sample colour and turbidity and automatically compensate to eliminate interference that would otherwise affect a standard fluorometer reading.

How is the sensor cleaned and calibrated?

Diagnosis, cleaning, and calibration are handled via the MA-CR Bluetooth/USB adapter and the uPyxis mobile or desktop app. Its short fluidic channel design is also easier to clean than fluorometers with a flat sensor face or a long, narrow fluidic cell.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Pyxis ST-765SS-CLO Chlorine Dioxide + pH Sensor – Sensor Only (Stainless Steel)

Stainless steel chlorine dioxide + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.

Pyxis ST-765P-O3 Ozone + pH Sensor (CPVC)

CPVC oxidizer + pH + temperature sensor measuring Ozone 0.00-2.00ppm with pH compensation to pH 9.0. Replaceable front-loading reference electrode, Bluetooth-ready with MA-CR adapter.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Pyxis ST-587 Inline PTSA + Turbidity Sensor
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?

Our engineers are ready to evaluate your requirements and recommend the right solution.