Stainless steel inline TTA corrosion inhibitor tracer sensor (0-10ppm). 4-20mA + RS-485, 7-pin.

The Pyxis ST-565T-SS is an inline sensor that measures tolyltriazole (TTA) / HST-HRA corrosion inhibitor levels, supporting closed-loop and cooling water treatment programmes. It reports concentration across a 0-10ppm range and communicates via 4-20mA analog output and RS-485 Modbus through a 7-pin connector. Its stainless steel body is built for high-pressure process line installations.
The Pyxis ST-565T-SS is an inline tracer sensor with a stainless steel body, built to measure tolyltriazole (TTA) / HST-HRA corrosion inhibitor levels in high-pressure closed-loop and cooling water treatment programmes. It gives operators continuous, real-time confirmation of corrosion inhibitor dosing in demanding process conditions.
The sensor covers a 0-10ppm range and communicates via a 4-20mA analog output and RS-485 Modbus digital signal, both wired through a 7-pin connector for integration with standard control and monitoring equipment.
It is intended for treatment providers and facility operators running closed-loop or cooling water systems on high-pressure lines that require a stainless steel sensor body.
Measures tolyltriazole (TTA) / HST-HRA corrosion inhibitor levels in real time across a 0-10ppm range, giving operators direct visibility into treatment chemical performance.
Dual 4-20mA analog and RS-485 Modbus outputs through a 7-pin connector let the sensor feed data straight into existing SCADA or controller setups.
The stainless steel housing withstands high-pressure process water service where standard sensor bodies would not be suitable.
It measures tolyltriazole (TTA) / HST-HRA corrosion inhibitor concentration for closed-loop and cooling water treatment programmes.
The ST-565T-SS has a stainless steel body, built for high-pressure process line service.
It covers a 0-10ppm range.
It provides 4-20mA analog output and RS-485 Modbus communication through a 7-pin connector.
Stainless steel dechlorination sensor measuring Free Chlorine (0-5ppm) and Sulfite (0-100ppm) simultaneously, plus pH. Sensor only, no flow reservoir. Dual 4-20mA + RS-485.
Inline digital refractometer measuring refractive index, %BRIX, and both mono-ethylene and mono-propylene glycol concentration in one sensor. Suited to closed-loop glycol systems, sugar process monitoring, and data centre cooling loops.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.