Stainless steel high-pressure inline fluorescein sensor, high range (0-500ppb). 4-20mA + RS-485, 7-pin.

The Pyxis ST-525SS-HR is an inline sensor that measures dye-tagged (fluorescein) treatment chemical dosing, supporting treatment chemical feed. It reports concentration across a 0-500ppb range and communicates via 4-20mA analog output and RS-485 Modbus through a 7-pin connector. Its stainless steel body is built for high-pressure process line installations.
The Pyxis ST-525SS-HR combines a high-range fluorescein tracer measurement with a stainless steel body rated for high-pressure process line installation. It tracks dye-tagged treatment chemical dosing across a 0-500ppb range, extending detection well beyond the standard sensor’s ceiling for higher-concentration treatment programs.
The stainless steel construction allows the sensor to be installed in demanding, high-pressure process water systems where a standard housing would not be appropriate. Readings are available through a 4-20mA analog output and RS-485 Modbus, both wired through a 7-pin connector.
This sensor suits treatment providers running higher-concentration dye-tagged chemistries on high-pressure boiler or process water lines who need continuous, real-time feed verification.
Measures dye-tagged (fluorescein) treatment chemical dosing in real time across a 0-500ppb range, giving operators direct visibility into treatment chemical performance.
Dual 4-20mA analog and RS-485 Modbus outputs through a 7-pin connector let the sensor feed data straight into existing SCADA or controller setups.
The stainless steel housing withstands high-pressure process water service where standard sensor bodies would not be suitable.
It measures dye-tagged fluorescein tracer across a 0-500ppb range, suited to higher-concentration monitoring applications.
Yes, its stainless steel body is built for high-pressure process line installations.
It outputs both a 4-20mA analog signal and RS-485 Modbus digital communication through a 7-pin connector.
It is an inline sensor that mounts directly into the process water line for continuous monitoring.
Inline fluorescence sensor for real-time chlorophyll-a (algae) monitoring, reagent-free. Suited to raw water intake and cooling water source monitoring.
Stainless steel chlorine dioxide + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.