Inline PTSA sensor for sea water reverse osmosis systems, with titanium solution ground (0-40ppb). 4-20mA + RS-485, 7-pin.
The Pyxis ST-500RO-Ti is an inline PTSA fluorometer built with a titanium solution ground for use in sea water reverse osmosis systems, measuring antiscalant tracer concentration across a 0-40ppb range. It tracks inhibitor dose in fluorescence-traced water treatment programmes and outputs via 4-20mA analog and RS-485 Modbus through a 7-pin connector.
The Pyxis ST-500RO-Ti is an inline PTSA fluorometer built with a titanium solution ground, designed specifically for use in sea water reverse osmosis systems.
It measures antiscalant tracer concentration across a 0-40ppb range, tracking inhibitor dose in fluorescence-traced water treatment programmes where standard sensor materials would be at greater risk from the corrosive, high-chloride sea water environment.
Output is via 4-20mA analog and RS-485 Modbus through a 7-pin connector, allowing it to integrate directly with plant control systems on sea water RO trains.
A titanium solution ground makes this sensor suitable for the more corrosive conditions found in sea water reverse osmosis systems.
The 0-40ppb range is calibrated for reverse osmosis antiscalant tracer dosing.
4-20mA analog and RS-485 Modbus outputs through a 7-pin connector allow straightforward wiring into a PLC or SCADA system.
The titanium solution ground is designed for use in sea water reverse osmosis systems, where the sensor is exposed to a highly corrosive, high-chloride environment.
It measures antiscalant tracer concentration across a 0-40ppb range, the same range as the standard ST-500RO.
The ST-500RO-Ti adds a titanium solution ground specifically for sea water RO service, whereas the standard ST-500RO is intended for general reverse osmosis applications.
Output is via 4-20mA analog and RS-485 Modbus through a 7-pin connector.
Stainless steel free chlorine + pH sensor, 0-5ppm, complete with FR-50 flow reservoir kit and rotameter. Dual 4-20mA + RS-485, 8-pin connector.
Inline digital refractometer measuring refractive index, %BRIX, and both mono-ethylene and mono-propylene glycol concentration in one sensor. Suited to closed-loop glycol systems, sugar process monitoring, and data centre cooling loops.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.