Dual-channel handheld fluorometer measuring PTSA (0-300ppb) and Fluorescent Polymer (0-20ppm) with colour and turbidity compensation.
The Pyxis SP-380P is a dual-channel handheld fluorometer that directly measures PTSA and Fluorescent (Tagged) Polymer, tracer chemicals widely used in cooling and process water applications. Using patent-pending optical measurement technology, it reads fluorescent polymer at 0-20ppm and PTSA at 0-300ppb while simultaneously compensating for colour and turbidity interference. The same measurement is also available as an inline sensor in the ST-588.
The Pyxis SP-380P is a dual-channel handheld fluorometer that directly measures PTSA and Fluorescent (Tagged) Polymer, two tracer chemicals widely used in cooling and process water treatment programs. Using patent-pending optical measurement technology, it reads fluorescent polymer across 0.0-20.0ppm and PTSA up to 300.0ppb (extendable to 500ppb via the uPyxis app), while simultaneously compensating for colour and turbidity interference.
No sample cuvette is required, and a built-in cleanliness check diagnostic flags a dirty sample cell before it affects results. The Pyxis Lab LOCK-IN feature stabilises the reading, and Bluetooth wireless calibration through the uPyxis app keeps the device configured and up to date in the field.
For continuous, unattended monitoring, the same dual measurement is also available as an inline sensor in the Pyxis ST-588, letting the SP-380P double as a verification tool for sites running that sensor.
Combining PTSA and Fluorescent Polymer measurement in one meter simplifies tracer monitoring for cooling and process water systems.
Colour and turbidity compensation, cleanliness diagnostics, and the LOCK-IN feature work together to keep readings repeatable.
It measures Fluorescent (Tagged) Polymer from 0.0-20.0ppm and PTSA from 0.0-300.0ppb, extendable to 500ppb via the uPyxis app.
No, the SP-380P requires no sample cuvette.
It automatically measures and compensates for colour and turbidity interference, and includes a built-in cleanliness diagnostic for the sample cell.
Yes, the same PTSA and tagged polymer measurement is available as an inline sensor in the Pyxis ST-588 Inline PTSA + Tagged Polymer Sensor.
Handheld fluorometer measuring in-vivo chlorophyll-a concentration in live algae cells for cooling water and surface water monitoring.
All-in-one pocket colorimeter measuring all primary oxidizing biocides and disinfectants, plus direct-read chlorine dioxide and bleach concentration.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.