Single-channel handheld fluorometer measuring fluorescent (tagged) polymer with colour and turbidity compensation.
The Pyxis SP-350P is a single-channel handheld fluorometer for direct measurement of fluorescent (tagged) polymer, a tracer chemical widely used in cooling and process water applications. Using patent-pending optical measurement technology, it reads polymer concentration from 0-20ppm while simultaneously compensating for colour and turbidity interference common in real-world water samples. The same measurement is also available as an inline sensor in the ST-590.
The Pyxis SP-350P is a single-channel handheld fluorometer that directly measures fluorescent (tagged) polymer, a tracer chemical widely used to monitor treatment dosing in cooling and process water systems. Using patent-pending optical measurement technology, it reads polymer concentration across a 0-20ppm range while simultaneously compensating for colour and turbidity interference found in real-world water samples.
No sample cuvette is required — samples are measured directly — and a built-in cleanliness check diagnostic flags a dirty sample cell before it skews results. The Pyxis Lab LOCK-IN feature holds the reading once it stabilises, and the water-proof, robust housing is built for field conditions, with Bluetooth wireless calibration through the uPyxis app.
For sites that also want continuous, unattended monitoring, the same fluorescent polymer measurement is available as an inline sensor in the Pyxis ST-590, making the SP-350P a natural companion for spot-checking and verifying inline sensor performance.
Simultaneous colour and turbidity compensation means fluorescent polymer readings stay accurate even in water with real-world interference.
Cuvette-free sampling and the LOCK-IN feature let operators take a stable, repeatable reading without extra sample handling.
It measures fluorescent (tagged) polymer concentration over a range of 0.1-20.0ppm, with precision of 0.1ppm and accuracy of ±1% or ±1.0ppm.
No, the SP-350P requires no sample cuvette — samples are measured directly in the device.
It automatically compensates for colour and turbidity interference, and includes a built-in cleanliness check to flag a dirty sample cell.
Yes, the same fluorescent polymer measurement is available as an inline sensor in the Pyxis ST-590 Inline Tagged Polymer Sensor.
Multi-parameter, multi-wavelength fluorometer, colorimeter, and turbidimeter with direct-read PTSA and Fluorescein, 65+ built-in reagent-based methods.
All-in-one pocket colorimeter measuring all primary oxidizing biocides and disinfectants, plus direct-read chlorine dioxide and bleach concentration.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.