Pocket meter measuring bleach concentration as mass/mass (0-16%) with simultaneous temperature compensation.
The Pyxis SP-210 is a handheld pocket analyzer that measures bleach concentration as mass/mass, expressed as chlorine (Cl2), for both manufactured concentrate and diluted electrolysis-produced sodium hypochlorite. Its direct-pour sample method and ambient-light compensation algorithm eliminate the need for sample vials or shielding. Automatic RTD temperature compensation delivers accurate readings across a wide range of sample temperatures and bleach forms.
The Pyxis SP-210 is a pocket-sized bleach analyzer that measures mass/mass concentration of sodium hypochlorite, expressed as chlorine (Cl2), covering both manufactured concentrate and diluted electrolysis-produced bleach. Its direct-pour sample method applies the bleach sample straight into the measurement cell, and built-in algorithm compensation for ambient light means samples never need to be shielded from light.
Using an LED-based UV light source to measure optical density, the SP-210 offers an expanded auto-resolution measurement range along with RTD temperature output and automatic temperature compensation, so readings stay accurate across a wide range of sample temperatures and bleach strengths.
Built for plant operators and water treatment personnel who need fast, reliable bleach strength checks in the field or on the production line, the SP-210 eliminates sample vials entirely and includes integrated cleanliness diagnostics to flag a dirty measurement cell before it affects results.
Automatic RTD temperature compensation and auto-resolution measurement let the SP-210 deliver reliable %Cl2 readings on both concentrated and diluted hypochlorite samples.
The direct-pour sample method and ambient-light compensation remove the need for sample vials or shielding, speeding up routine bleach concentration checks.
The SP-210 measures bleach concentration from 0.01-16% mass/mass, expressed as chlorine (Cl2), with accuracy of ±2% of the reading value or ±0.1% of the unit range.
No. The SP-210 uses a direct-pour sample method — bleach is applied directly to the measurement cell, so no separate sample vials are needed.
No. The SP-210 includes algorithm compensation for ambient light, so samples do not need to be shielded during measurement.
Yes. The sample cell is compatible with concentrated liquid bleach solutions as well as diluted electrolysis-produced sodium hypochlorite, and RTD temperature compensation keeps readings accurate across sample temperatures and forms.
Handheld multimeter measuring pH (0-14), ORP (±1,500mV), Conductivity (0-15,000uS/cm), Turbidity (0-100NTU), and Free & Total Chlorine (0-10.00ppm DPD).
Single-channel handheld fluorometer measuring fluorescent (tagged) polymer with colour and turbidity compensation.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.