Skip to main content

Autoflo Technology

Pyxis ST-500RO Inline PTSA Sensor for Reverse Osmosis

Inline PTSA sensor for RO systems (0-40ppb). 4-20mA + RS-485, 7-pin.

Pyxis
PTSA Fluorometer
Inline Sensors Line

Pyxis ST-500RO Inline PTSA Sensor for Reverse Osmosis

Model:
ST-500RO
Brand:
Pyxis

The Pyxis ST-500RO is an inline PTSA fluorometer designed for reverse osmosis antiscalant tracer dosing applications, measuring inhibitor concentration across a 0-40ppb range. It tracks inhibitor dose in fluorescence-traced water treatment programmes and outputs via 4-20mA analog and RS-485 Modbus through a 7-pin connector.

RO-specific calibration — 0-40ppb range matched to reverse osmosis antiscalant tracer dosing
Standard control integration — 4-20mA analog and RS-485 Modbus outputs via a 7-pin connector
RO-specific calibration — 0-40ppb range matched to reverse osmosis antiscalant tracer dosing

Description

The Pyxis ST-500RO is an inline PTSA fluorometer purpose-built for reverse osmosis antiscalant tracer dosing applications, measuring inhibitor concentration across a 0-40ppb range.

This narrower, RO-matched range gives operators of RO plants a precise, real-time check that antiscalant dosing is tracking correctly ahead of the membranes, helping protect against scale formation.

It tracks inhibitor dose in fluorescence-traced water treatment programmes and outputs via 4-20mA analog and RS-485 Modbus through a 7-pin connector for integration with plant control systems.

Why Use This

Purpose-Built for RO Systems

The 0-40ppb range is calibrated for reverse osmosis antiscalant tracer dosing rather than general cooling water programmes.

Real-Time Dose Verification

Continuous PTSA fluorescence measurement confirms antiscalant tracer concentration is being maintained at the target dose.

Simple Control Integration

4-20mA analog and RS-485 Modbus outputs through a 7-pin connector allow straightforward wiring into a PLC or SCADA system.

Applications

  • Reverse osmosis antiscalant tracer dosing — confirms dosing is reaching target ahead of RO membranes
  • Scale prevention monitoring in RO pretreatment
  • PLC/SCADA-integrated dose control on RO trains

FAQ

What water treatment application is this sensor designed for?

The ST-500RO is designed for reverse osmosis antiscalant tracer dosing applications.

Why is the measurement range narrower than other PTSA sensors in the range?

The 0-40ppb range is matched to typical RO antiscalant dosing levels, which are lower than the general inhibitor dosing programmes other ST-500 variants cover.

How does it output measurements to plant controls?

Output is via 4-20mA analog and RS-485 Modbus through a 7-pin connector.

Is this sensor suitable for sea water RO systems?

This standard version is intended for general RO service; the ST-500RO-Ti variant with a titanium solution ground is the option built specifically for sea water RO systems.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Pyxis ST-765SS-DCL Free Chlorine + Sulfite + pH Sensor – Sensor Only (Stainless Steel)

Stainless steel dechlorination sensor measuring Free Chlorine (0-5ppm) and Sulfite (0-100ppm) simultaneously, plus pH. Sensor only, no flow reservoir. Dual 4-20mA + RS-485.

Pyxis ST-765P-CLO Chlorine Dioxide + pH Sensor (CPVC)

CPVC oxidizer + pH + temperature sensor measuring Chlorine Dioxide (ClO2) 0.00-5.00ppm (auto-range) with pH compensation to pH 9.0. Replaceable front-loading reference electrode, Bluetooth-ready with MA-CR adapter.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Pyxis ST-500RO Inline PTSA Sensor for Reverse Osmosis
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?

Our engineers are ready to evaluate your requirements and recommend the right solution.