Inline temperature + chlorine dioxide sensor (0-3,500ppm). Dual 4-20mA + RS-485, 7-pin.

The Pyxis ST-601 is an inline sensor that measures temperature-compensated chlorine dioxide (ClO2) concentration, supporting chlorine dioxide disinfection monitoring. It reports concentration across a 0-3,500ppm range and communicates via 4-20mA analog output and RS-485 Modbus through a 7-pin connector.
The Pyxis ST-601 is an inline sensor that measures temperature-compensated chlorine dioxide (ClO2) concentration, supporting chlorine dioxide disinfection monitoring in water treatment systems. Temperature compensation helps maintain accurate readings as process conditions change, giving operators reliable visibility into ClO2 feed performance.
It reports concentration across a wide 0-3,500ppm range and provides dual 4-20mA analog outputs plus RS-485 Modbus communication, all wired through a 7-pin connector, enabling the sensor to feed two independent control or monitoring points.
It is designed for facilities and treatment providers using chlorine dioxide for disinfection who need continuous, temperature-compensated feed verification tied into their control systems.
Measures temperature-compensated chlorine dioxide (ClO2) concentration in real time across a 0-3,500ppm range, giving operators direct visibility into treatment chemical performance.
Dual 4-20mA analog and RS-485 Modbus outputs through a 7-pin connector let the sensor feed data straight into existing SCADA or controller setups.
It measures temperature-compensated chlorine dioxide (ClO2) concentration, supporting chlorine dioxide disinfection monitoring.
It covers a 0-3,500ppm range.
The ST-601 provides two independent 4-20mA analog outputs plus RS-485 Modbus, allowing readings to feed two separate control or monitoring points from one sensor.
It is an inline sensor that mounts directly into the process water line for continuous monitoring.
Inline digital refractometer measuring refractive index, %BRIX, and both mono-ethylene and mono-propylene glycol concentration in one sensor. Suited to closed-loop glycol systems, sugar process monitoring, and data centre cooling loops.
Real-time inline PTSA sensor for tracking inhibitor dose in cooling and boiler water treatment programmes. Measures PTSA using fluorescence technology across 0–300ppb with automatic colour and turbidity compensation, holding accuracy even in samples with iron contamination or elevated turbidity.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.