Inline temperature + % chlorine sensor for bleach concentration (0-16%). Dual 4-20mA + RS-485, 7-pin.

The Pyxis ST-600 is an inline sensor that measures temperature-compensated % chlorine concentration, supporting bleach (sodium hypochlorite) feed monitoring. It reports concentration across a 0-16% range and communicates via 4-20mA analog output and RS-485 Modbus through a 7-pin connector.
The Pyxis ST-600 is an inline sensor that measures temperature-compensated % chlorine concentration, supporting bleach (sodium hypochlorite) feed monitoring in water treatment applications. Temperature compensation helps maintain measurement accuracy as process water conditions shift, giving operators a more reliable read on bleach feed performance.
It reports concentration across a 0-16% range and provides dual 4-20mA analog outputs plus RS-485 Modbus communication, all wired through a single 7-pin connector. The dual analog outputs allow the sensor to feed two separate control or monitoring points independently.
This sensor is designed for facilities and treatment providers that dose bleach for disinfection and need continuous, temperature-compensated feed verification integrated into their control systems.
Measures temperature-compensated % chlorine concentration in real time across a 0-16% range, giving operators direct visibility into treatment chemical performance.
Dual 4-20mA analog and RS-485 Modbus outputs through a 7-pin connector let the sensor feed data straight into existing SCADA or controller setups.
It measures temperature-compensated % chlorine concentration, supporting bleach (sodium hypochlorite) feed monitoring.
It reports concentration across a 0-16% range.
The ST-600 provides dual 4-20mA analog outputs plus RS-485 Modbus, allowing it to feed readings to two separate control or monitoring points from a single sensor.
It is an inline sensor that mounts directly into the process water line for continuous monitoring.
Stainless steel free chlorine + pH sensor, 0-5ppm, complete with FR-50 flow reservoir kit and rotameter. Dual 4-20mA + RS-485, 8-pin connector.
Real-time inline PTSA sensor for tracking inhibitor dose in cooling and boiler water treatment programmes. Measures PTSA using fluorescence technology across 0–300ppb with automatic colour and turbidity compensation, holding accuracy even in samples with iron contamination or elevated turbidity.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.