Drop-in design stainless steel high-pressure fluorescein sensor (0-60ppb). Requires ST-007 stainless tee (sold separately). 4-20mA + RS-485, 8-pin.

The Pyxis ST-525SS-T is an inline sensor that measures dye-tagged (fluorescein) treatment chemical dosing, supporting treatment chemical feed. It reports concentration across a 0-60ppb range and communicates via 4-20mA analog output and RS-485 Modbus through an 8-pin connector. Its stainless steel body is built for high-pressure process line installations. The drop-in design installs into the ST-007 stainless tee, sold separately, for straightforward field mounting.
The Pyxis ST-525SS-T is a drop-in inline fluorescein tracer sensor built with a stainless steel body for high-pressure process water applications. It tracks dye-tagged treatment chemical dosing across a 0-60ppb range, giving operators continuous visibility into chemical feed performance.
Unlike the standard ST-525SS, this drop-in variant is designed to install into the companion ST-007 stainless steel tee, which is sold separately. This design simplifies field mounting and removal for service, without needing to break into the main process line fitting each time.
Data is available via 4-20mA analog output and RS-485 Modbus through an 8-pin connector, making it suitable for treatment providers who need serviceable, high-pressure tracer monitoring with straightforward wiring into control systems.
Measures dye-tagged (fluorescein) treatment chemical dosing in real time across a 0-60ppb range, giving operators direct visibility into treatment chemical performance.
Dual 4-20mA analog and RS-485 Modbus outputs through an 8-pin connector let the sensor feed data straight into existing SCADA or controller setups.
The stainless steel housing withstands high-pressure process water service where standard sensor bodies would not be suitable.
Yes, this drop-in sensor requires the ST-007 stainless steel tee, which is sold separately, for mounting into the process line.
It tracks dye-tagged fluorescein treatment chemical across a 0-60ppb range.
The drop-in ST-525SS-T variant uses an 8-pin connector for its wiring, compared to the 7-pin connector on the standard ST-525SS.
Yes, its stainless steel construction is built for high-pressure process line installations.
Stainless steel chlorine dioxide + pH sensor, 0-5ppm, complete with FR-50 flow reservoir kit and rotameter. Dual 4-20mA + RS-485, 8-pin connector.
Inline digital refractometer measuring refractive index, %BRIX, and both mono-ethylene and mono-propylene glycol concentration in one sensor. Suited to closed-loop glycol systems, sugar process monitoring, and data centre cooling loops.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.