Standard biofilm sensor for most industrial applications, with strong corrosion resistance suited to seawater use.

Alvim
Electrochemical Sensor
Water Treatment Line

Alvim A001S3 Biofilm Sensor

Model:
A001S3
Brand:
Alvim

The Alvim A001S3 is a standard biofilm sensor that provides real-time detection and monitoring of bacterial fouling in industrial pipelines, cooling towers and process water. Its corrosion-resistant titanium and PVC construction makes it particularly well suited to seawater applications. The sensor communicates via 4-20 mA and RS485/MODBUS RTU for integration into existing monitoring systems.

Seawater-ready construction — corrosion-resistant titanium and PVC materials suit demanding seawater applications
Early fouling detection — measures 1-100% of surface covered by biofilm, flagging bacterial growth from its first layer
Seawater-ready construction — corrosion-resistant titanium and PVC materials suit demanding seawater applications

Description

The Alvim A001S3 is Alvim’s standard biofilm sensor, providing real-time detection and monitoring of bacterial fouling in industrial pipelines, cooling towers and process water. Its titanium working electrode, zinc counter electrode and PVC threaded connector give it corrosion-resistant construction that is particularly well suited to seawater applications.

The sensor mounts via a 1″ BSPP threaded connection and measures sensitivity of 1-100% of surface covered by biofilm, detecting the first bacterial layer. It operates across a temperature range of -10 to +60°C, at pressures below 10 bar, and requires water conductivity greater than 10 µS/cm and oxygen levels above 1 ppm at maximum sensitivity. Power is supplied at 12/24V DC ±20%, 500 mA, with data output via 4-20 mA and RS485/MODBUS RTU over a 6-wire cable.

It is suited to cooling tower water treatment, Legionella monitoring, Clean-in-Place processes, and general food safety and process water monitoring.

Why Use This

Corrosion-Resistant Design

Titanium and PVC construction stands up to seawater and other corrosive process water, extending sensor service life.

Real-Time Fouling Detection

Detects the first bacterial layer and measures up to 100% surface coverage, giving early warning before biofilm becomes a larger problem.

Simple Integration

A standard 1″ BSPP threaded connection plus 4-20 mA and RS485/MODBUS RTU outputs allow straightforward installation into existing pipelines and control systems.

Applications

  • Cooling tower water treatment — real-time biofilm monitoring in cooling water systems
  • Legionella monitoring — detection of bacterial fouling conditions linked to Legionella risk
  • Clean-in-Place (CIP) processes — monitoring for biofilm before and after cleaning cycles
  • Food safety and process water monitoring — general bacterial fouling detection in process water
  • Seawater-fed industrial pipelines — corrosion-resistant construction suited to seawater service

FAQ

What does the A001S3 detect?

It detects and monitors bacterial fouling (biofilm), measuring 1-100% of the surface covered by biofilm and flagging growth from the first bacterial layer.

Is the A001S3 suitable for seawater applications?

Yes, its titanium and PVC construction is corrosion-resistant and particularly well suited to seawater use.

How does the sensor connect to process piping?

It connects via a 1″ BSPP thread.

What data outputs does it provide?

It communicates via 4-20 mA and RS485/MODBUS RTU, wired with a 6-wire cable under 8mm external diameter.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Pyxis RT-200 PRISM High Temperature Inline Refractometer

High-temperature inline digital refractometer measuring refractive index, %BRIX, and glycol concentration up to 120°C. Stainless steel Tri-Clamp body, IP67, built-in Bluetooth 5.0.

Pyxis ST-500 Inline PTSA Sensor

Real-time inline PTSA sensor for tracking inhibitor dose in cooling and boiler water treatment programmes. Measures PTSA using fluorescence technology across 0–300ppb with automatic colour and turbidity compensation, holding accuracy even in samples with iron contamination or elevated turbidity.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Alvim A001S3 Biofilm Sensor
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?

Our engineers are ready to evaluate your requirements and recommend the right solution.