Skip to main content

Autoflo Technology

Fluimac Phoenix P1000 AODD Pump

Fluimac Phoenix P1000 seal-less AODD pump delivers up to 1050 lt/min for heavy-duty industrial fluid transfer.

Fluimac
Air-Operated
AODD Pump Range

Fluimac Phoenix P1000 AODD Pump

Model:
P1000
Brand:
Fluimac

The Fluimac Phoenix P1000 is an air-operated double diaphragm (AODD) pump rated for a maximum flow of 1050 lt/min, available in multiple casing materials to match different chemical compatibility needs. Its seal-less, valve-ball design allows dry-running without damage, self-priming to 5 m of dry suction lift, and safe deadheading against a closed discharge line. Diaphragm, ball, seat, and gasket materials can be combined to suit specific application requirements.

Dry-run safe — seal-less valve-ball design tolerates dry running without pump damage
Safe deadheading — pump can run against a closed discharge line without damage
Dry-run safe — seal-less valve-ball design tolerates dry running without pump damage

Description

The Fluimac Phoenix P1000 is an air-operated double diaphragm (AODD) pump rated for a maximum flow of 1050 lt/min, designed for high-volume industrial fluid transfer. It is available in multiple casing materials, allowing the wetted-parts construction to be matched to the chemical compatibility requirements of the application, and each casing option can be further configured with a range of diaphragm, ball, seat, and gasket material combinations.

The pump uses a seal-less, valve-ball design that can dry-run without damage, self-prime to 5 m of dry suction lift, and safely deadhead against a closed discharge line without pump damage. Fluid connections are 3″ BSPP-DN80 with a 3/4″ BSPP air connection, and the pump operates on up to 8 bar of air pressure, delivering a maximum head of 80 m and a wet suction lift of 9.8 m. It can pass solids up to 12 mm and handle fluids up to 55,000 cps in viscosity, with a displacement of approximately 9750 cc per stroke.

An ATEX rating of II 3/3 G Ex h IIB T4 Gc / II 3 D Ex h IIIB T135°C Dc X qualifies the P1000 for use in classified hazardous areas, making it suitable for demanding industrial and process environments where both flow capacity and area classification are factors. Autoflo can advise on the correct diaphragm, ball, seat, and gasket composition code for a given application.

Why Use This

Dry-run and deadhead protection

The seal-less valve-ball design allows the pump to run dry or against a closed discharge without damage, reducing downtime risk.

Chemical compatibility flexibility

Multiple casing and wetted-part material combinations let the P1000 be configured for a wide range of fluids.

ATEX-rated for hazardous areas

Certified for use in classified gas and dust zones, suiting demanding industrial environments.

Applications

  • High-volume industrial fluid transfer — max flow rate of 1050 lt/min
  • Chemical transfer — casing and wetted-part material combinations selected for chemical compatibility
  • Dry-run tolerant duties — self-primes to 5 m dry suction lift without seal damage
  • Closed-discharge (deadheaded) process lines — pump withstands deadheading without damage
  • High-viscosity fluid transfer — handles fluids up to 55,000 cps
  • Hazardous area installations — ATEX rated for classified zones

FAQ

What is the maximum flow rate of the Phoenix P1000?

The Phoenix P1000 is rated for a maximum flow of 1050 lt/min.

Can the P1000 run dry without damage?

Yes. Its seal-less, valve-ball design allows dry-running without damage, self-priming to 5 m of dry suction lift, and safe deadheading against a closed discharge line.

What casing materials are available?

The P1000 is available in multiple casing materials to match different chemical compatibility requirements, with diaphragm, ball, seat, and gasket combinations configurable for specific applications — consult Autoflo for the correct composition code.

Is the Phoenix P1000 rated for hazardous areas?

Yes. It carries an ATEX rating of II 3/3 G Ex h IIB T4 Gc / II 3 D Ex h IIIB T135°C Dc X.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Fluimac Phoenix Food PF120 AODD Pump

Fluimac Phoenix Food PF120 is a 316 stainless steel AODD pump with Tri-Clamp fittings for hygienic food and beverage transfer.

Fluimac Phoenix P90 AODD Pump

Air-operated double diaphragm pump rated for 100 lt/min flow, built for seal-less, self-priming chemical and fluid transfer.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Fluimac Phoenix P1000 AODD Pump
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?

Our engineers are ready to evaluate your requirements and recommend the right solution.