Inline turbidimeter, ultra-high range (0-10,000NTU). 4-20mA + RS-485, 7-pin.

The Pyxis ST-735 is an inline turbidimeter built for process and treated water clarity monitoring across an ultra-high measurement range of 0-10,000NTU. It provides continuous readings through both 4-20mA analog and RS-485 Modbus outputs via a 7-pin connector, making it suitable for integration into existing control and SCADA systems.
The Pyxis ST-735 is an inline turbidimeter engineered for continuous clarity monitoring of process and treated water. Mounted directly in the pipeline, it covers an ultra-high measurement range of 0-10,000NTU, making it suited to streams carrying significantly more suspended material than a standard process turbidimeter can read.
Readings are available through both 4-20mA analog and RS-485 Modbus outputs via a single 7-pin connector, so the sensor drops into existing control and SCADA architectures without added wiring complexity. This dual-output design gives plant operators and system integrators flexibility in how the ST-735 reports into their monitoring stack.
It is best suited to facilities that need dependable, real-time visibility into heavily loaded process or treated water lines, where standard-range turbidimeters would saturate or lose accuracy.
Covers turbidity readings up to 10,000NTU, making it suitable for process streams too heavily loaded for standard turbidimeters.
Dual 4-20mA and RS-485 Modbus outputs let it connect to existing analog loops or digital control systems.
It measures across an ultra-high range of 0-10,000NTU, designed for process streams that exceed the range of standard process turbidimeters.
It outputs via both 4-20mA analog and RS-485 Modbus through a single 7-pin connector, allowing integration with existing SCADA or control panels.
The ST-735 is an inline turbidimeter, mounted directly into the process or treated water line for continuous monitoring rather than submersible tank deployment.
The standard ST-735 is supplied as a complete unit; a sensor-only variant without the tee assembly kit (ST-735-NT) is also available for installations with existing mounting hardware.
316L stainless steel inline fluorometer measuring PTSA (0–500ppb) and turbidity (0–200NTU) with colour and turbidity compensation. Rated to 290psi, suited to data centre and high-pressure cooling systems.
Stainless steel monochloramine + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.