Solenoid-Driven Diaphragm Dosing Pump | Autoflo Technology
:root {
--accent: #800059;
--accent-tint: #FAEEF5;
--cta-bg: #FEBE4F;
--cta-text: #331A00;
--dark-bg: #2A001D;
--bg: #FFFFFF;
--bg-alt: #F3F4F6;
--text: #111827;
--muted: #4B5563;
--border: #E5E7EB;
--container: 1240px;
--ease: cubic-bezier(0.22, 1, 0.36, 1);
}
*, *::before, *::after { box-sizing: border-box; margin: 0; padding: 0; }
html { scroll-behavior: smooth; overflow-x: clip; width: 100%; margin: 0; padding: 0; }
body { font-family: 'Inter', system-ui, sans-serif; background: var(--bg); color: var(--text); -webkit-font-smoothing: antialiased; overflow-x: clip; line-height: 1.7; }
a { color: inherit; text-decoration: none; }
img { display: block; max-width: 100%; }
button { font-family: inherit; cursor: pointer; border: none; background: none; }
.container { max-width: var(--container); margin: 0 auto; padding: 0 40px; }
.btn { display: inline-flex; align-items: center; gap: 8px; font-size: 14px; font-weight: 600; border-radius: 4px; padding: 13px 28px; transition: all 0.3s var(--ease); white-space: nowrap; cursor: pointer; position: relative; overflow: hidden; font-family: inherit; border: none; }
.btn::after { content: ''; position: absolute; top: 0; left: -100%; width: 50%; height: 100%; background: linear-gradient(to right, transparent, rgba(255,255,255,0.2), transparent); transform: skewX(-25deg); transition: left 0.6s var(--ease); pointer-events: none; }
.btn:hover::after { left: 150%; }
.btn-accent { background: linear-gradient(135deg, #ffd080, #FEBE4F); color: var(--cta-text); box-shadow: 0 4px 12px rgba(254,190,79,0.2); }
.btn-accent:hover { background: linear-gradient(135deg, #ffe9a8, #ffd080); transform: translateY(-2px); box-shadow: 0 8px 20px rgba(254,190,79,0.3); }
.cat-intro { padding: 100px 0; background: var(--bg); border-bottom: 1px solid var(--border); }
.cat-intro-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 64px; align-items: center; }
.cat-intro-image { position: relative; border-radius: 12px; overflow: hidden; aspect-ratio: 4 / 5; background: var(--bg-alt); box-shadow: 0 24px 48px rgba(0,0,0,0.08); }
.cat-intro-image img { width: 100%; height: 100%; object-fit: cover; transition: transform 0.5s; }
.cat-intro-image:hover img { transform: scale(1.03); }
.cat-intro-badge { position: absolute; top: 16px; left: 16px; background: var(--dark-bg); color: #fff; font-size: 11px; font-weight: 600; letter-spacing: 0.08em; text-transform: uppercase; padding: 5px 12px; border-radius: 4px; border: 1px solid rgba(255,255,255,0.15); }
.cat-intro-label { font-size: 14px; font-weight: 600; letter-spacing: 0.05em; color: var(--accent); text-transform: uppercase; display: inline-block; margin-bottom: 8px; }
.cat-intro-title { font-family: 'Outfit', system-ui, sans-serif; font-size: clamp(32px, 4vw, 40px); font-weight: 600; color: var(--text); letter-spacing: -0.02em; line-height: 1.15; margin-top: 4px; }
.cat-intro-desc { font-size: 17px; color: var(--muted); line-height: 1.7; margin-bottom: 24px; }
.feature-list { display: flex; flex-direction: column; gap: 12px; margin-bottom: 32px; }
.feature-item { display: flex; align-items: flex-start; gap: 12px; }
.feature-check { width: 20px; height: 20px; border-radius: 50%; background: var(--accent-tint); border: 1px solid rgba(128,0,89,0.2); flex-shrink: 0; margin-top: 1px; display: flex; align-items: center; justify-content: center; }
.feature-check svg { width: 11px; height: 11px; color: var(--accent); }
.feature-item p { font-size: 15px; color: var(--muted); line-height: 1.6; }
.feature-item strong { color: var(--text); font-weight: 600; }
.reveal { opacity: 0; transform: translateY(20px); transition: opacity 0.65s ease, transform 0.65s ease; }
.reveal.is-visible { opacity: 1; transform: none; }
@media (max-width: 1024px) { .container { padding: 0 24px; } }
@media (max-width: 900px) { .cat-intro-grid { grid-template-columns: 1fr; gap: 40px; } }
Injecta Electromagnetic Pumps
Solenoid-Driven Diaphragm Dosing Pump
Electromagnetic Precision, Adjustable on the Fly
A solenoid-driven diaphragm pump uses an electromagnet to pulse a PTFE-faced diaphragm back and forth at a set stroke length and frequency. Each backstroke draws chemical in through a ceramic-ball check valve; each forward stroke pushes a fixed dose out through a second check valve — with no rotating seals in contact with the chemical. Dosing rate is adjusted two ways: stroke length (a manual dial, for coarse constant-flow adjustment) and stroke frequency (electronically, on digital models, for proportional dosing driven by an external signal, pulse count, or ppm setpoint). A PVDF pump head keeps the wetted parts compatible with the aggressive chemicals common in industrial, water treatment, and swimming pool applications across Malaysia.
Electromagnetic actuation — no motor or gearbox, just a solenoid coil pulsing the diaphragm at a set frequency
Dual adjustment — stroke length for coarse flow setting, stroke frequency for proportional/digital dosing
PVDF head, ceramic balls, PTFE diaphragm — wetted parts built for chemical compatibility and long service life
Three Injecta lines — Athena, Olimpia, and GEA, spanning compact general-purpose to high-flow base-mounted models
Request Engineering Quote
(function () {
const obs = new IntersectionObserver(entries => {
entries.forEach(e => { if (e.isIntersecting) { e.target.classList.add('is-visible'); obs.unobserve(e.target); } });
}, { threshold: 0.08 });
document.querySelectorAll('.reveal').forEach(el => obs.observe(el));
})();