Drop-in design stainless steel high-range fluorescein sensor (0-500ppb). Requires ST-007 stainless tee. 4-20mA + RS-485, 8-pin.

The Pyxis ST-525SS-HR-T is an inline sensor that measures dye-tagged (fluorescein) treatment chemical dosing, supporting treatment chemical feed. It reports concentration across a 0-500ppb range and communicates via 4-20mA analog output and RS-485 Modbus through an 8-pin connector. Its stainless steel body is built for high-pressure process line installations. The drop-in design installs into the ST-007 stainless tee, sold separately, for straightforward field mounting.
The Pyxis ST-525SS-HR-T is a drop-in, high-range fluorescein tracer sensor with a stainless steel body built for high-pressure process water applications. It measures dye-tagged treatment chemical dosing across a 0-500ppb range, suiting treatment programs that run at higher tracer concentrations.
As a drop-in design, it installs into the companion ST-007 stainless steel tee, sold separately, which simplifies field mounting and service access on high-pressure lines without disturbing the main process fitting. Data is transmitted via a 4-20mA analog signal and RS-485 Modbus through an 8-pin connector.
It is suited to treatment providers needing serviceable, high-concentration tracer monitoring on demanding, high-pressure boiler or process water systems.
Measures dye-tagged (fluorescein) treatment chemical dosing in real time across a 0-500ppb range, giving operators direct visibility into treatment chemical performance.
Dual 4-20mA analog and RS-485 Modbus outputs through an 8-pin connector let the sensor feed data straight into existing SCADA or controller setups.
The stainless steel housing withstands high-pressure process water service where standard sensor bodies would not be suitable.
Yes, the ST-525SS-HR-T is a drop-in sensor that requires the ST-007 stainless steel tee, sold separately, for mounting into the process line.
It covers a 0-500ppb range for dye-tagged fluorescein tracer, suited to higher-concentration treatment programs.
Yes, its stainless steel construction is built for high-pressure process line installations.
It provides 4-20mA analog output and RS-485 Modbus communication through an 8-pin connector.
High-temperature inline digital refractometer measuring refractive index, %BRIX, and glycol concentration up to 120°C. Stainless steel Tri-Clamp body, IP67, built-in Bluetooth 5.0.
Stainless steel chlorine dioxide + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.