Drop-in design stainless steel high-pressure PTSA + fluorescent tagged-polymer sensor (0-200ppb / 0-20ppm). Requires ST-009 stainless tee. Dual 4-20mA + RS-485, 8-pin.

The Pyxis ST-588SS-T is a drop-in inline dual-parameter sensor with a stainless steel body for high-pressure service, measuring PTSA and fluorescent tagged polymer together in a single probe across a 0-200ppb / 0-20ppm range. It must be installed with the ST-009 stainless tee, sold separately, and outputs dual 4-20mA analog and RS-485 Modbus signals through an 8-pin connector.
The Pyxis ST-588SS-T is a drop-in inline dual-parameter sensor with a stainless steel body for high-pressure service, measuring PTSA and fluorescent tagged polymer together in a single probe across a 0-200ppb / 0-20ppm range.
Combining both measurements in one high-pressure-rated, drop-in probe reduces the number of separate instruments needed on demanding inline installations running combined treatment programmes.
It must be installed with the ST-009 stainless tee, sold separately, and outputs dual 4-20mA analog and RS-485 Modbus signals through an 8-pin connector.
A stainless steel drop-in body is rated for high-pressure inline installations when paired with the ST-009 stainless tee.
Measuring PTSA and fluorescent tagged polymer together reduces the number of insertion points needed on the process line.
Dual 4-20mA analog and RS-485 Modbus outputs through an 8-pin connector allow straightforward wiring into a PLC or SCADA system.
No, it is a drop-in sensor design that must be installed with the ST-009 stainless tee, which is sold separately.
It measures PTSA and fluorescent tagged polymer together in a single probe, across a 0-200ppb / 0-20ppm range.
Yes, it has a stainless steel body built for high-pressure service.
Output is dual 4-20mA analog and RS-485 Modbus through an 8-pin connector.
Stainless steel sulfite + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.
Real-time inline PTSA sensor for tracking inhibitor dose in cooling and boiler water treatment programmes. Measures PTSA using fluorescence technology across 0–300ppb with automatic colour and turbidity compensation, holding accuracy even in samples with iron contamination or elevated turbidity.
Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.
PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.
Our engineers are ready to evaluate your requirements and recommend the right solution.