Skip to main content

Autoflo Technology

Pyxis ST-588SS-T Inline Drop-In Stainless Steel PTSA + Fluorescent Polymer Sensor (requires ST-009 Tee)

Drop-in design stainless steel high-pressure PTSA + fluorescent tagged-polymer sensor (0-200ppb / 0-20ppm). Requires ST-009 stainless tee. Dual 4-20mA + RS-485, 8-pin.

Pyxis
PTSA + Polymer Sensor
Inline Sensors Line

Pyxis ST-588SS-T Inline Drop-In Stainless Steel PTSA + Fluorescent Polymer Sensor (requires ST-009 Tee)

Model:
ST-588SS-T
Brand:
Pyxis

The Pyxis ST-588SS-T is a drop-in inline dual-parameter sensor with a stainless steel body for high-pressure service, measuring PTSA and fluorescent tagged polymer together in a single probe across a 0-200ppb / 0-20ppm range. It must be installed with the ST-009 stainless tee, sold separately, and outputs dual 4-20mA analog and RS-485 Modbus signals through an 8-pin connector.

High-pressure durability — stainless steel drop-in body rated for high-pressure service
Dual-parameter measurement — tracks PTSA inhibitor dose and tagged-polymer dose from one probe
High-pressure durability — stainless steel drop-in body rated for high-pressure service

Description

The Pyxis ST-588SS-T is a drop-in inline dual-parameter sensor with a stainless steel body for high-pressure service, measuring PTSA and fluorescent tagged polymer together in a single probe across a 0-200ppb / 0-20ppm range.

Combining both measurements in one high-pressure-rated, drop-in probe reduces the number of separate instruments needed on demanding inline installations running combined treatment programmes.

It must be installed with the ST-009 stainless tee, sold separately, and outputs dual 4-20mA analog and RS-485 Modbus signals through an 8-pin connector.

Why Use This

Built for High-Pressure Service

A stainless steel drop-in body is rated for high-pressure inline installations when paired with the ST-009 stainless tee.

Two Tracers, One Probe

Measuring PTSA and fluorescent tagged polymer together reduces the number of insertion points needed on the process line.

Standard Control Integration

Dual 4-20mA analog and RS-485 Modbus outputs through an 8-pin connector allow straightforward wiring into a PLC or SCADA system.

Applications

  • High-pressure inline installations requiring combined PTSA and tagged-polymer monitoring
  • Combined scale inhibitor and dispersant/polymer dosing programmes
  • Installations paired with the ST-009 stainless tee

FAQ

Does this sensor come with the tee needed for installation?

No, it is a drop-in sensor design that must be installed with the ST-009 stainless tee, which is sold separately.

What does it measure?

It measures PTSA and fluorescent tagged polymer together in a single probe, across a 0-200ppb / 0-20ppm range.

Is it rated for high-pressure service?

Yes, it has a stainless steel body built for high-pressure service.

How does it output to plant controls?

Output is dual 4-20mA analog and RS-485 Modbus through an 8-pin connector.

Download

D25 Product Datasheet
PDF · 1.2 MB
Installation Manual
PDF · 0.8 MB

Resources

How to Size a Chemical Dosing Pump for Water Treatment
Technical Article · 8 min read
Understanding Water-Powered vs Electric Dosing Pumps
Technical Article · 6 min read
Poultry Medication Dosing — Case Study
Case Study · Selangor Poultry Farm
You May Also Need

Related Products

Pyxis ST-765SS-SO3 Sulfite + pH Sensor – Sensor Only (Stainless Steel)

Stainless steel sulfite + pH sensor, 0-5ppm, sensor only with no flow reservoir. Dual 4-20mA + RS-485, 8-pin connector.

Pyxis ST-500 Inline PTSA Sensor

Real-time inline PTSA sensor for tracking inhibitor dose in cooling and boiler water treatment programmes. Measures PTSA using fluorescence technology across 0–300ppb with automatic colour and turbidity compensation, holding accuracy even in samples with iron contamination or elevated turbidity.

Controllers
Pyxis pH / ORP Controller

Compact dual-channel controller for pH and ORP monitoring with direct pulse output to dosing pumps.

Accessories
Injection Quill & Check Valve

PVDF injection quill with integral non-return valve for safe chemical injection into pressurised pipelines.

Animal Line

Other Models in This Line

Pyxis ST-588SS-T Inline Drop-In Stainless Steel PTSA + Fluorescent Polymer Sensor (requires ST-009 Tee)
Explore Range
Stay Informed

Latest Resources

Initiate a Project

Need help with selection or sizing?

Our engineers are ready to evaluate your requirements and recommend the right solution.