Why Voltage and Frequency Affect the Dosing Rate of a Motor-Driven Dosing Pump — And What To Do When They Don’t Match
Voltage and frequency directly determine motor speed, and motor speed determines dosing rate in mechanically driven pumps like the Injecta Taurus. Here’s why supply quality causes silent underdosing, and how to prevent it.
Why Stroke Rate Matters More Than You Think When Dosing Viscous Chemicals
Most engineers size a metering pump based on two things: the required flow rate and the discharge pressure. These are the right starting points. But for viscous chemicals, there is a third variable that determines whether the pump actually delivers what the datasheet says it will — stroke rate. Get the stroke rate wrong for […]